Waterproof Casing Pipe
S312 waterproof casing is mainly used in the pipeline through the wall where there is vibration or have strict waterproof working conditions, is a high-performance waterproof casing, rigid waterproof casing is suitable for general pipeline through the wall, and flexible waterproof casing is suitable for vibration or strict waterproof requirements of the scene.
Overview
Structure
312 rigid waterproof casing
Steel pipe: this is the main part of the casing, used to carry the pipe.
Wing ring: ring made of steel plate set on the steel pipe, play a fixed and protective role.
Filler: usually use oil hemp, asbestos cement and other materials for filling, filling tightly pounded to prevent pipe vibration and expansion and deformation
312 flexible waterproof casing
Steel casing: this is one of the main structures of flexible waterproof casing, made of steel, providing basic support and protection functions.
Wing ring: wing ring is a ring-shaped steel plate, usually installed on the outside of the casing, used to increase the rigidity and waterproof performance of the casing.
Retaining ring: The retaining ring is used to fix and support the pipe, preventing the pipe from moving inside the casing and ensuring the stability of the pipe.
Sealing ring: flexible waterproof casing is usually equipped with a sealing ring to ensure the waterproof effect when the pipe passes through the wall. Sealing rings are divided into type I and type II, which are suitable for different waterproofing requirements.
Application Scene
Construction field: basement waterproofing, bathroom waterproofing, kitchen waterproofing, pipeline crossing waterproofing, civil defense projects, underground pipe corridors. Industrial buildings, pools, tunnels, bridges.
Industrial field: water treatment equipment, paper equipment, chemical equipment
Municipal and water conservancy field: municipal drainage systems, water conservancy projects
Installing the Data Sheet | |||||||||
Name | flexible waterproof casing | Rigid waterproof casing | |||||||
S312-R | S312-G | ||||||||
DN | Length ( | Be applicable Wall | Applicable Tube Outside diameter | Wingring diameter | Length=(Wall Thickness) | Applicable Tubing OD | Wing ring diameter | ||
Type A | Type B | Type A | Type B | ||||||
50 | 380 | 300 | 60 | 177 | 200 | 60 | 60 | 225 | 225 |
80 | 384 | 300 | 89 | 217 | 200 | 89 | 93 | 251 | 251 |
125 | 386 | 300 | 133 | 257 | 200 | 133 | 143 | 301 | 315 |
200 | 386 | 300 | 219 | 350 | 200 | 219 | 220 | 394 | 394 |
300 | 388 | 300 | 325 | 462 | 200 | 325 | 322.8 | 498 | 498 |
400 | 392 | 300 | 426 | 565 | 200 | 426 | 425.6 | 621 | 621 |
450 | 394 | 300 | 480 | 613 | 200 | 480 | 476.8 | 671 | 671 |
500 | 394 | 300 | 530 | 673 | 200 | 530 | 528 | 720 | 720 |
600 | 407 | 300 | 630 | 787 | 200 | 630 | 630.8 | 822 | 810 |
700 | 409 | 300 | 720 | 877 | 200 | 720 | 733 | 911 | 924 |
800 | 411 | 300 | 820 | 987 | 200 | 820 | 836 | 1011 | 1027 |
900 | 413 | 300 | 920 | 1087 | 200 | 920 | 939 | 1113 | 1132 |
1000 | 415 | 300 | 1020 | 1187 | 200 | 1020 | 1041 | 1213 | 1234 |