GB/T2032-1993 Marine Fire Hydrant Valve
Overview
Main Introduction
The fire hydrant valve refers to a special valve installed on the fire hydrant, which mainly plays the role of cutting off the water supply pipeline of the fire hydrant.
Main Types Provisions of GB/T2032-1993 Marine Fire Hydrant Valve
Type A - Straight type fire hydrant with flange size according to GB 569;
Type AS - Straight type fire hydrant with flange size according to GB 2501;
Type B - Right Angle type hydrant with flange dimensions according to GB 569;
Type BS - Right Angle type fire hydrant with flange dimensions according to GB 2501.
Drawing
1-Valve Body 2-Fire Fitting 3-Fitting Cover
Main Specification of GB/T2032-1993 Marine Fire Hydrant Valve
A Type &B Type
Nominal Diameter (DN) | External dimensions | Flange Connection Size | |||||||||||
L | L1 | H | L2 | H1 | D | D1 | D2 | n | Th | ||||
A | B | A | B | A | B | ||||||||
40 | 240 | 134 | 85 | 70 | 167 | 140 | 90 | 70 | 125 | 93 | 74 | 6 | M14 |
50 | 258 | 145 | 85 | 80 | 170 | 140 | 100 | 80 | 135 | 103 | 84 | ||
65 | 294 | 170 | 100 | 95 | 200 | 170 | 120 | 90 | 155 | 123 | 104 |
AS Type &BS Type
Nominal Diameter (DN) | External dimensions | Flange Connection Size | |||||||||||
L | L1 | H | L2 | H1 | D | D1 | D2 | n | Th | ||||
AS | BS | AS | BS | AS | BS | ||||||||
40 | 240 | 134 | 85 | 70 | 167 | 140 | 90 | 70 | 150 | 110 | 88 | 4 | M14 |
50 | 258 | 145 | 85 | 80 | 170 | 140 | 100 | 80 | 165 | 125 | 102 | ||
65 | 294 | 170 | 100 | 95 | 200 | 170 | 120 | 90 | 185 | 145 | 122 |