DPNP/TPNP/FPNP Double/Three/Four core EPR insulated and polychloroprene (PCP) sheathed flexible cord 0.6/1KV
Applications
This product is used in ships,petrol platforms and offshore buildings for power,light and control systems,usually used for fixed installation in most areas and open deck in ships.
Overview
Construction of DPNP/TPNP/FPNP Double/Three/Four core EPR insulated and polychloroprene (PCP) sheathed flexible cord 0.6/1KV:
Components | Code | Material/Description |
Conductor | D(T,F) | Tinned annealed copper wire, bunch stranded |
Insulation | P | EP rubber |
Sheath | N | PCP |
Characteristic | P | Portable and flexible cable |
Rated Voltage | 0.6/1KV |
Standards applied of DPNP/TPNP/FPNP Double/Three/Four core EPR insulated and polychloroprene (PCP) sheathed flexible cord 0.6/1KV:
Design:JIS C 3410
Flame Retardant:60332-1
Flame Retardant(FA type):IEC 60332-2-22
Nominal size of DPNP/TPNP/FPNP Double/Three/Four core EPR insulated and polychloroprene (PCP) sheathed flexible cord 0.6/1KV:
No.of cores | Conductor Size | Overall Diameter | Approx. Weight | ||
DPNP, TPNP, FPNP | DPNP, TPNP, FPNP | ||||
mm² | Stranding | mm | ±mm | kg/km | |
2 | 0.75 | 24/0.20 | 9.7 | 0.4 | 130 |
1 | 32/0.20 | 9.9 | 0.4 | 135 | |
1.5 | 30/0.25 | 10.8 | 0.4 | 165 | |
2.5 | 49/0.25 | 11.8 | 0.5 | 205 | |
4 | 33/0.30 | 13.1 | 0.5 | 265 | |
6 | 82/0.30 | 14.5 | 0.6 | 340 | |
3 | 0.75 | 24/0.20 | 10.2 | 0.4 | 145 |
1 | 32/0.20 | 10.7 | 0.4 | 160 | |
1.5 | 30/0.25 | 11.4 | 0.5 | 190 | |
2.5 | 49/0.25 | 12.5 | 0.5 | 240 | |
4 | 33/0.30 | 14.1 | 0.6 | 325 | |
6 | 82/0.30 | 15.6 | 0.6 | 420 | |
4 | 0.75 | 24/0.20 | 11.3 | 0.5 | 180 |
1 | 32/0.20 | 11.8 | 0.5 | 200 | |
1.5 | 30/0.25 | 12.6 | 0.5 | 235 | |
2.5 | 49/0.25 | 14.1 | 0.6 | 310 | |
4 | 33/0.30 | 15.6 | 0.6 | 410 | |
6 | 82/0.30 | 17.2 | 0.7 | 525 |