CPT Series Ejector Pump

CPT Series Ejector Pump


     CPT marine ejector pump is kind of right-angle ship jetting water for ship drainage system or drainage equipment which is applied in conveying liquid, gas mixture, the mixture of gas and liquid, powder, vacuum working atmosphere and deodorizing. Choosing different shape and suitable type according to real matched system is wisdom choice.

     Certificate: CCS



Overview

Picture/drawing of CPT marine ejector pump:

CPT.jpg

Model Explanation: CPT 10-0.7

CP —Marine ejector pump

10—Flow 10m3/h

0.7—Working water pressure 0.7Mpa

T—Perpendicular type

Parameter of CPT marine ejector pump:

Type

Work water/ Intel/ Outlet flange

(mm)

Capacity

(m3/h)

         

         Pressure

(Mpa)



       Wastage

(m3/h)


    Hs

    (m)

Delivery

(m)

Weight

(kg)

CPT5-0.3T

32/50/50

5

0.3

6

4

5

19.5

CPT10-0.3T

40/65/65

10

0.3

12

4

5

23.5

CPT15-0.3 T

50/65/80

15

0.3

19

4

5

28

CPT15-0.5T

50/65/80

15

0.5

24

7

11

28

CPT20-0.3T

50/65/80

20

0.3

24

4

5

31

CPT30-0.3T

65/100/100

30

0.3

36

4

5

50

CPT40-0.3T

65/100/100

40

0.3

47

4

6

49.5

CPT50-0.3T

80/125/125

50

0.3

55

3

6

75

CPT100-0.3T

125/175/150

100

0.3

110

3

8

94.5

CPT5-0.7T

25/50/32

5

0.7

3.6

4

8

14

CPT10-0.7T

32/50/50

10

0.7

7

4

8

20

CPT20-0.7T

50/65/80

20

0.7

14

4

8

28.5

CPT30-0.7T

50/80/65

30

0.7

21

4

8

32

CPT50-0.7T

65/100/80

50

0.7

35

4

8

48

CPT60-0.7T

80/125/125

60

0.7

50

6

6

55.5

CPT80-0.7T

80/125/125

80

0.7

90

5

10

75

CPT100-0.7T

80/150/125

100

0.7

60

2

9

71.5

CPT150-0.7T

80/150/150

150

0.7

100

2

9

77

CPT200-0.7T

125/200/200

200

0.7

120

2

9

106

CPT10-1.0T

50/50/65

10

1.0

16.7

5

2

16

CPT50-1.0T

80/125/125

50

1.0

64

5

2

52

CPT100-0.2T

200/200/250

100

0.2

305

3

7

120

CPT Series ejector pump in Factory




Contact Us