Marine Smoke Tube Boiler
Vertical smoke tube boilers are boilers in a vertical shape with smoke flowing in vertically arranged tubes.
The combustion part adopts a double-layer grate combustion chamber, which can rapidly increase temperature and pressure. It can also fully combust the unburned gas after secondary combustion and remove smoke and dust.
Contact via mail: <hs10@cqhisea.com>
Overview
Specifications of Marine Vertical Smoke Tube Boiler
Model | Main parameters and dimensions of boiler | |||||||
evaporate capacity(kg/h) | working pressure(MPa) | outline dimensions | weight(kg) | water capacity(m³) | ||||
A | B | C | D | |||||
WHG0.5-0.7 | 500 | 0.7 | 2510 | 1830 | 1610 | DN200 | 3144 | 1 |
2WY0.5-0.7 | 500 | 0.7 | 2875 | 1830 | 1690 | DN200 | 2102 | 0.8 |
WHG0.7-0.7 | 700 | 0.7 | 2730 | 1950 | 1700 | DN230 | 3300 | 1.1 |
2WY0.7-.0.7 | 700 | 0.7 | 3200 | 1875 | 1700 | DN250 | 2700 | 0.9 |
WHG 1-0.7 | 1000 | 0.7 | 3250 | 1955 | 1750 | DN300 | 3500 | 1.3 |
2WY1.2-0.7 | 1200 | 0.7 | 3460 | 2060 | 2132 | DN350 | 4800 | 1.5 |
WHG 1.5-0.7 | 1500 | 0.7 | 3630 | 2000 | 2050 | DN350 | 5410 | 2 |
2WY1.5-0.7 | 1500 | 0.7 | 4016 | 2060 | 2280 | DN350 | 4675 | 2.4 |
WHG2-0.7 | 2000 | 0.7 | 4050 | 2100 | 2050 | DN400 | 6480 | 2.3 |
2WY2.7-0.7 | 2700 | 0.7 | 4546 | 2332 | 2140 | DN450 | 6500 | 3.5 |
2WY3-0.7 | 3000 | 0.7 | 4554 | 2300 | 2400 | DN450 | 8106 | 4.7 |