Marine Mushroom Duct

Marine Mushroom Duct


Marine bacterial ventilation tubes are usually installed on the open deck of ships for natural and mechanical ventilation devices. Its design features include reasonable structure, simple construction, complete specifications, wide applicability and good weathertightness.

Overview

Features:

1. Scope and purpose of use

It can be fixed on natural ventilation and mechanical ventilation devices on various ship decks for ventilation.

2. Operating standards

The manufacturing, testing, and acceptance technical conditions of the ventilation fan comply with the provisions of GB/T295-2000 "Marine Fungal Ventilation Chimney".

3. Characteristics

All the above ventilation tubes have the characteristics of reasonable structure, easy on/off, beautiful appearance, good inflation, and reliable sealing. They can meet the broad needs of the shipping industry.

4. Marking

The mark for DN=500 ventilation tank is C500 CB/T295-2000 ventilation tank.

Matters needing attention:

1. The hard particles transported in flammable and explosive mixed gases should not exceed 150mg/m3, and the diameter should not exceed 2mm.

2. Protective brass mesh should be installed on the suction pipe to prevent static sparks and other objects from being sucked in, ensuring the safety of explosion-proof ventilation fans.

3. When the external cable enters the junction box for fixation, the junction box itself, its entry device, and the cable must be strictly sealed, and no rainwater is allowed to enter the junction box.

4. The cable must be grounded, especially for explosion-proof motors.

5. When connecting the explosion-proof ventilation fan to the air duct, there should be no tilting of the casing due to rigid connection. It is even more prohibited to forcibly connect and add the weight of the pipeline to the fan to avoid deformation of the casing.

6. The power of the electric motor used in the ventilation fan refers to the strict control of the motor current by adjusting the air intake during operation under specific working conditions, combined with mechanical losses and the appropriate safety factor. Do not exceed the rated current of the motor.

Structure and main dimensions:

Type

Name Nominal dia DN(mm)
AInside on-off Hood ventilator150~350
BOuter on-off Obturation ventilator

260~1400

COuter on-off Obturation Axial Flow ventilator

260~1400

DFixed Ventilated Canister

260~1400

EInside on-off Obturation Ventilator

150~350

FOuter on-off Obturation Ventilator

150~900