CEV90/NA EPR Insulation Fire Resistant Armor Type Marine Power Cable

CEV90/NA EPR Insulation Fire Resistant Armor Type Marine Power Cable


Applications

This product is used in ships,petrol platforms and offshore buildings for power,light and control systems,usually used for fixed installation in most areas and open deck in ships.

Overview

Construction of CEV90/NA EPR Insulation Fire Resistant Armor Type Marine Power Cable:

ItemCodeMaterial/Description
Series codeCMarine &offshore power cable
Conductor
Tinned (or plain)stranded,annealed copper wire
InsulationEMica glass tape+ EPR
Inner sheathVPVC
Armor9Galvanized steel wire braid
Outer sheath0Without outer sheath
Sheath color
Black or Specifed Color
FlammabilityNAFire resistant

Standards applied of CEV90/NA EPR Insulation Fire Resistant Armor Type Marine Power Cable:

Design:IEC 60092-350、353

Conductor:IEC 60228

Insulation & sheath:IEC 60092-360

Fire Resistant:IEC 60331

Flame Retardant:IEC 60332-1

Flame Retardant:IEC 60332-3-22

Nominal size of CEV90/NA EPR Insulation Fire Resistant Armor Type Marine Power Cable:

No. of cores&Cross
section
O.D.
 
Weight

No. of cores&Cross
section
O.D.
 
Weight

NominalToleranceNominalTolerance
No. X mm²mm±kg/kmNo. X mm²mm±kg/km
1x16.70.5 723x7035.2 1.8 2606 
1x1.570.5 79 3x9540.3 2.1 3519 
1x2.57.40.5 96 3x12044.0 2.2 4312 
1x47.90.5 114 3x15048.4 2.5 5227
1x68.50.5 137 3x18553.8 2.7 6464 
1x109.5 0.5 189 4x112.30.7 239 
1x1610.8 0.5 251 4x1.513.20.7 271 
1x2512.7 0.7 389 4x2.514.20.8 342 
1x3514.0 0.7 491 4x415.70.8 419 
1x5015.6 0.8 636 4x617.10.9 523 
1x7017.7 0.9 851 4x1019.7 1.0 719 
1x9520.2 1.0 1135 4x1622.5 1.2 986 
1x120
21.8
1.1
1372
4x2527.0 1.4 1453 
1x15024.11.216624x3529.8 1.5 1887 
1x18526.71.420444x5034.2 1.7 2480 
1x24029.91.526174x7039.1 2.0 3367 
1x30033.0 1.7 3195 4x9544.9 2.3 4553 
2x110.50.6 150 4x12049.1 2.5 5585 
2x1.511.10.6 193 4x15053.9 2.7 6777 
2x2.512.10.7 238 5x113.50.7 274 
2x413.40.7 283 7x114.70.8 339 
2x614.50.8 345 10x118.81.0 466 
2x1017.1 0.9 459 12x119.41.0 518 
2x1619.5 1.0 613 14x120.31.1 586 
2x2523.2 1.2 887 16x121.61.1 646 
2x3525.5 1.3 1136 19x122.91.2 739 
2x5029.0 1.5 1466 24x126.81.4 919 
2x7033.2 1.7 1949 27x127.61.4 994 
2x9538.1 1.9 2619 30x128.61.5 1089 
2x12041.6 2.1 3177 33x129.61.5 1172 
2x1+E11.10.6 187 37x130.91.6 1293 
2x1.5+E11.90.6 218 5x1.514.30.8 319 
2x2.5+E130.7 264 7x1.515.70.8 390 
2x4+E14.20.8 320 10x1.519.81.0 547 
2x6+E15.40.8 421 12x1.520.51.1 613 
2x10+E18.0 0.9 582 14x1.5
21.7
1.1
683
2x16+E20.5 1.1 791 16x1.523.11.2767
3x25+E26.31.4 1359 19x1.524.51.3 867 
3x35+E28.41.5 1786 24x1.528.71.5 1093 
3x50+E32.61.7 2221 27x1.529.21.5 1186 
3x70+E36.8 1.9 2995 30x1.530.51.6 1301 
3x95+E42.2 2.2 4016 33x1.531.61.6 1403 
3x120+E46.7 2.4 4992 37x1.5331.7 1549 
3x150+E50.3 2.56124 5x2.515.60.8 394 
3x185+E56.3 2.87701 7x2.516.90.9 501 
3x111.10.6 187 10x2.521.71.2 693 
3x1.511.90.6 218 12x2.522.71.2 792 
3x2.5130.7 264 14x2.523.81.3 889 
3x414.20.8 320 16x2.525.31.3 999 
3x615.40.8 421 19x2.526.61.4 1138 
3x1018.0 0.9 582 24x2.531.41.6 1435 
3x1620.5 1.1 791 27x2.5321.7 1565 
3x2524.4 1.3 1145 30x2.533.41.7 1719 
3x3526.9 1.4 1480 33x2.534.71.8 1857 
3x5030.8 1.6 1941 37x2.536.21.9 2056 